Patch panels, keystone jacks and accessories for 19 inch racks

Patching organises the network cabling in a rack, from the panel where cables from wall outlets terminate through to the switch, along with everything that mounts, tidies and protects the installation. The range covers pre-wired RJ45 Cat6 patch panels and blank keystone panels, Cat6 and Cat6A keystone jacks and couplers, SC or LC fibre panels, plus fixed and sliding shelves, blanking inserts, cable guides, cage nuts and mounting kits. The UniFi line from Ubiquiti adds its keystone accessories, mounting ears and a rackmount Ethernet surge protector.

When a small business cables a new floor, a 24 or 48 port panel takes the runs from the offices and short patch leads connect it to the switch. Moving a desk then means moving a lead, without touching the fixed cabling. In a server room, a shelf holds a firewall, a small NAS or a rackmount enclosure for Raspberry Pi boards, whereas a wall cabinet in a workshop calls for cable glands, sleeving and ties to protect the cables entering it.

For a panel, the category comes first, with Cat6 serving most office networks and Cat6A suited to cabling that must carry 10 Gbit/s along its full length. The termination method changes the installation work, since 110 connections are punched down with an impact tool on a pre-wired panel, while a blank keystone panel takes snap-in jacks, some tool-free, and can mix copper and fibre on the same face. For shelves, the choice lies between fixed or sliding, vented or solid, 1U or 2U, reading the maximum load and the depth, which is adjustable on some models.

Before buying, check the usable depth of the rack and the spacing of its rails. A shelf that is too long hits the rear door, and a kit such as the Cisco one for Catalyst lists the rack formats it fits, 19", 23", 24" or ETSI. Cage nuts are not always supplied with equipment, so it is worth keeping a set to hand. A shielded FTP jack adds nothing on unshielded UTP cable, and a Cat6A coupler does not raise the category of a link installed in Cat6.

For a home network or a single workstation, a small keystone panel, a few hook-and-loop straps and RJ45 dust covers are enough to keep things tidy. Across a company estate, consistency matters more, with the same jack category from one rack to the next, blanking inserts on empty units to guide airflow and vertical managers that keep every lead traceable. A school or local authority powering cameras and Wi-Fi access points over PoE benefits from fitting an Ethernet surge protector between exposed cabling and its switches.

StarTech.com mainly supplies vented sliding shelves, some with cable management arms, 0U vertical organisers and a Cat6 panel with 110 termination. Ubiquiti offers UniFi keystone jacks, couplers and blanks in multipacks, while Delock, Digitus, Logilink, Equip, Lanberg, Goobay and Inter-Tech cover panels, sleeving and cable fastening. Rittal, APC with its NetShelter cabinets, Efb and Intellinet provide cabinet accessories, from cable guides to mounting rails and roof fan units, and Lenovo a rack kit for IBM tape libraries.

Frequently asked questions

Pre-wired patch panel or blank keystone panel, which should I choose?

A pre-wired panel, often with 110 termination, has fixed ports of a single category and is punched down with an impact tool. It suits uniform, long-term copper cabling.

A blank keystone panel takes snap-in jacks chosen one by one. It can mix RJ45 Cat6, Cat6A or fibre couplers, and a damaged jack is replaced without changing the whole panel.

Should new network cabling be Cat6A rather than Cat6?

Cat6 is enough for most office networks. Cat6A makes sense when cabling must carry 10 Gbit/s over long runs or power many devices over PoE.

The whole chain has to match, cable, jacks and couplers, because a single Cat6 component brings the link down to that category.

Fixed or sliding rack shelf, what difference does it make in use?

A fixed shelf holds a device that is rarely handled, and some models offer adjustable depth to fit the rack. A sliding shelf pulls out of the rack so the back of the equipment can be reached without removing it.

Vented versions help heat escape, and the maximum load, shown on each product page, depends on the model.

What are blanking inserts and cable organisers for in a rack?

Blanking inserts close off empty rack units or unused keystone slots. They stop hot air recirculating to the front of the equipment and keep dust out.

Horizontal guides and 0U vertical organisers route leads along the sides, keeping each link traceable and access to the ports clear.

Does a rack mounting kit fit every rack?

No, it depends on both the equipment and the rack. A manufacturer kit, such as the Cisco one for Catalyst or the Lenovo one for IBM tape libraries, targets specific devices and lists the rack formats it accepts.

Also check the usable depth and whether cage nuts are included, as they are not always supplied.

Why fit an Ethernet surge protector in a network rack?

An Ethernet surge protector sits between the cabling and the switches to absorb surges travelling along the cables, especially those serving outdoor areas or other buildings.

The 1U rackmount UniFi model handles 24 ports, supports 10 Gbit/s and passes PoE power through up to PoE+++.