Network cabinets, server racks and 19-inch enclosures

A network cabinet or server rack brings switches, patch panels, servers, UPS units and routers together in one place, fixed to mounting rails in the standard 19-inch format. The range covers wall-mounted cabinets with doors, closed floor-standing cabinets, open-frame racks with 2 or 4 posts, mobile racks from the Ubiquiti UniFi line and IP55 enclosures for indoor and outdoor use. Alongside them sit the accessories that finish an installation, such as side panels, roofs, plinths, sliding rails and fans.

In a small office, a 9U or 12U wall cabinet keeps the switch, router and patch panel out of reach without taking up floor space. A company server room is better served by a closed, lockable 42U cabinet, where servers, storage and the UPS share power and cooling. For a workshop, a lab or a technical room where people work on the kit often, an open rack on castors gives access to the cabling from every side.

Height is measured in U, the standard unit for rack-mounted equipment, with common sizes such as 6U, 9U, 12U, 15U, 18U, 22U, 24U, 26U and 42U. Mounting depth, given in cm on each product page (40.6 cm, 50.8 cm or 60.9 cm for wall cabinets), decides which equipment will fit, and several racks have adjustable posts. The number of posts also matters, as 2 posts are enough for switches and light panels while a server on rails needs 4 posts. Then come the load rating, from 90 kg for a wall cabinet to several hundred kilos for a floor-standing model, the door type, glass, perforated or steel mesh, and locking.

Before buying, compare the depth of your longest device with the usable mounting depth, leaving room at the back for cables and plugs. A server or UPS mounts on matching rails, such as the kits APC offers for its Smart-UPS SRT, and non-rackable devices sit on a 1U shelf. Empty spaces are closed with blanking panels so hot air does not flow back to the front, and a closed cabinet full of active equipment needs ventilation. For a wall-mounted model, the wall has to carry the weight of the loaded cabinet, and a hinged mount makes the back of the equipment easier to reach.

A home user tidying up a household network will usually manage with a small open rack or a UniFi mobile rack. A business running a fleet of sites benefits from identical cabinets everywhere, with metered or switched PDUs, side panels and air containment. In a school or local authority building, a lockable cabinet in a corridor or classroom keeps hands off the equipment, and an IP55 enclosure suits damp or dusty rooms.

StarTech.com covers small and medium sizes with its wall cabinets and open racks, with or without castors and often supplied as a kit. Rittal offers its VX IT server cabinets and VX baying systems, APC its NetShelter SX and Easy Rack, Digitus its Unique cabinets and Dynamic wall enclosures, while Lanberg, EFB and Intellinet provide floor-standing and wall-mounted cabinets. HPE with side and blanking panels, Eaton with SmartRack shelves and Tripp Lite wall cabinets, Vertiv and Middle Atlantic with mounting accessories round out the fit-out of the rack.

Frequently asked questions

Should I choose an open rack or a closed cabinet?

An open rack gives access to cabling from every side and ventilates naturally, which suits a locked technical room or a lab. A closed cabinet, with a glass or perforated door and a lock, protects equipment from dust and tampering in an office or corridor, but its ventilation needs more thought.

What is the difference between a 2-post and a 4-post rack?

A 2-post rack holds equipment at the front only, which is enough for switches, patch panels and light devices. A 4-post rack supports equipment at both front and back, which a server or UPS on rails requires, and its depth is often adjustable depending on the model.

How do I work out how many U I need?

Add up the height in U of each planned device, shown on its product page, including shelves, patch panels and cable managers. Leaving some free space for network growth avoids replacing the cabinet at the first addition, and any empty slots can be closed with blanking panels.

What cabinet depth do I need for a server?

The usable mounting depth has to exceed the depth of the server, with room left at the back for power and network cables. Shallow wall cabinets, around 40.6 cm or 50.8 cm, mainly take switches and patching, whereas a server is better housed in a 4-post floor-standing cabinet, according to the dimensions its manufacturer gives.

Is a wall-mounted cabinet enough for a small office network?

For a switch, a router, a patch panel and perhaps a small NAS on a 1U shelf, a 9U or 12U wall cabinet is usually enough. Check that the wall can carry the weight of the loaded cabinet, as the load rating is listed on the product page, for example 90 kg depending on the model. A hinged mount makes rear access easier.

Which accessories should I plan for with a network cabinet?

Depending on the equipment, a cabinet is completed with shelves for non-rackable devices, sliding rails for servers and UPS units, blanking panels to guide airflow and a PDU to distribute power. Side panels, roofs, plinths and fans can be added to close up a rack or improve its cooling.

When is an IP55 enclosure the right option?

An IP55 enclosure, such as the Ubiquiti UniFi Junction Utility or some EFB wall enclosures, protects equipment against dust and water jets. It suits damp rooms, workshops, warehouses or outdoor installations, where a standard cabinet would let in dust and moisture.