UPS units to protect servers, racks and workstations
A UPS, or uninterruptible power supply, takes over from the mains during a power cut or voltage drop. This gives you time to save your work and shut down servers, NAS units and workstations cleanly. The range covers line-interactive and online double-conversion units in tower, rack and convertible rack/tower formats, alongside refurbished models. Network management cards, battery extensions and replacement cartridges, rail kits and power cords sit alongside them, around the APC Smart-UPS, Easy UPS and Galaxy ranges, Vertiv Liebert, Bluewalker PowerWalker and UniFi.
For an office workstation or a router, a small 750 VA tower unit with a few C13 outlets covers a brief outage and gives the PC time to shut down. In a server rack, a 2U unit rated at 1500 VA leaves space for other equipment, and its network card shuts the machines down when the battery runs low. A server room or sensitive equipment calls for an online unit rated at 8000 VA or 10 kW, or a three-phase 400 V model for the heaviest installations. The UniFi UPS, a managed line-interactive unit, fits naturally alongside a UniFi network.
Power ratings are given in both VA and watts, and the 2 figures differ, a 1500 VA unit delivering for example 1000 W. Base your choice on the wattage your equipment draws, and leave a margin. The technology comes next. A line-interactive unit corrects voltage fluctuations and switches to battery when the power fails, whereas an online double-conversion unit delivers a continuously regenerated sine wave with no transfer time at all. After that, compare the number of C13 and C19 outlets, the rack height (1U, 2U or 3U) and the battery type, either lead-acid or lithium-ion, which is lighter and lasts longer.
Check the connections before you buy. Most rack units have IEC C13 and C19 outputs, which connect to equipment through C13 to C14 cords. The most powerful models are hardwired to a terminal block or use an IEC 309 connector, so they need an electrician to install them. Each range has its own battery extensions for longer runtime, and the network management card has to match the slot provided, such as the SmartSlot on Smart-UPS units. Sizing on VA alone skews the calculation, and the rail kit for a rack unit is easily forgotten.
At home or on a standalone desk, a tower unit with automatic voltage regulation (AVR) and a USB connection that tells the PC to shut down is enough. In a small business, sticking to one range simplifies monitoring through SNMP or Modbus network cards, replacing battery cartridges and adding refurbished units to existing equipment. When racks are spread across several buildings, as in a town or a secondary school, every UPS can be checked remotely without travelling to each site.
APC is the most widely stocked brand, from tower and rack Smart-UPS units with SmartConnect to three-phase Easy UPS units and Galaxy battery cabinets. Eaton offers rack/tower models with lithium-ion batteries and matching extensions. Vertiv brings its Liebert range, and Bluewalker supplies PowerWalker units with an SNMP card and a rackmount kit. FSP, Roline with its rack-mounted LineSecure range, Gembird, Cyber Power, Green Cell, Nitram, Conceptronic, Digitus, Lenovo and HPE complete the selection.
Frequently asked questions
What is the difference between a line-interactive and an online UPS?
A line-interactive UPS corrects voltage fluctuations and switches to battery during an outage, which is enough for workstations, a NAS or a small rack. An online double-conversion unit regenerates the power continuously with no transfer time. It protects servers and sensitive equipment, as the online Smart-UPS units rated at 8000 VA or 10 kW do.
How do I size a UPS when it is rated in both VA and watts?
A UPS shows 2 values, apparent power in VA and real power in watts, which is lower. For example, a 1500 VA unit delivers 1000 W. Add up the wattage of the equipment you need to protect and leave a margin, because a fully loaded UPS only runs for a very short time.
Should I choose a tower or a rack-mounted UPS?
A tower unit stands on the floor or a desk and suits a single workstation or a small room. A rack unit mounts in a 19-inch rack and takes up 1U, 2U or 3U depending on the model. Convertible rack/tower models work in either setup. Check whether the rail kit is included, as it is sometimes sold separately.
What does a network management card add to a UPS?
A network management card connects the UPS to the local network. You can then monitor its status, receive alerts and trigger a clean shutdown of your servers. Depending on the model, it supports SNMP, Modbus or environmental sensors. It fits a dedicated slot, such as the SmartSlot on Smart-UPS units, and must match the UPS range.
Lead-acid or lithium-ion, which battery suits a UPS better?
Lead-acid batteries are still the most common, and dedicated cartridges replace them once they wear out. Lithium-ion batteries, found in some Eaton models and in APC Galaxy cabinets, are lighter and age more slowly. That counts for a rack that is hard to reach or for a fleet that you want to maintain as little as possible.
How can I extend the runtime of a UPS?
On models that support them, external battery extensions in rack or tower format connect to the UPS and extend its runtime. They are specific to each range, such as the Eaton battery modules or APC battery cabinets, and their voltage must match the UPS. If you cannot add batteries, a more powerful unit running at a lower load will last longer.