Power distribution units for server and network racks

A rack PDU, or power distribution unit, feeds the servers, switches and storage arrays mounted in a 19-inch cabinet. The range covers horizontal 1U strips, vertical PDUs fitted at the back of the rack, basic, metered and network-switched models. Lindy's IPower Switch range, Bachmann's BN PRO and IT PDU Basic or APC's NetShelter units are typical examples.

In a small business network cabinet, a 1U strip with French sockets is often enough to plug in the router, switch and NAS with their original power adapters. In a server room, machines with dual power supplies are split across 2 PDUs on 2 separate circuits, so a failure on one side stops nothing. At an unstaffed remote site, a switched PDU restarts a frozen device from its web interface, saving a technician the journey.

Socket type comes first. C13 outlets suit most servers and network equipment, C19 outlets serve more powerful supplies, French sockets take devices supplied with a standard mains plug, and Bachmann's Combo outlets accept either IEC format. Next comes the level of management, from plain distribution to power metering and outlet-by-outlet switching, as on Lindy's IPower Switch Classic and Pro, some versions of which combine C13 and C19 outlets. Rated load, 2500 W on several Lindy units, and single or three-phase supply on APC NetShelter PDUs complete the choice.

Before buying, check the PDU's input. A C20 inlet, found on the Lindy models, connects to a C19 outlet on a UPS or a main PDU, or to a suitable cord, not straight into a wall socket. Also check the space available, one rack unit for a horizontal strip or rear clearance for a vertical model, along with your devices' power cords. A common mistake is adding equipment without comparing total consumption with the load rating of the PDU and the circuit feeding it.

For a small network cabinet, a basic 1U strip with French sockets is usually enough. A business running several racks benefits from metered PDUs to track each cabinet's consumption, and switched models for its remote sites. In a school or local authority, Bachmann versions with residual current monitoring (RCM) warn of an insulation fault, while their built-in circuit breakers isolate an overloaded group of outlets without cutting power to the whole comms room.

Bachmann covers the range most widely, with aluminium-profile PDUs, three-phase versions and surge protection modules. Lindy stands out for network control of its IPower Switch units, via Ethernet and a web interface, with an RS-232 port on some models. APC brings NetShelter Advanced Metered PDUs for data centre racks, and Bluewalker a 19-inch bypass unit for servicing a UPS without powering down the equipment. Eaton and HPE also feature among the brands on offer.

Frequently asked questions

What is the difference between a basic, a metered and a switched PDU?

A basic PDU simply distributes power. A metered PDU displays or reports consumption, which helps avoid overloading a circuit and track a rack's usage. A switched PDU, such as the Lindy IPower Switch, turns each outlet off and on remotely, so a frozen device can be restarted without anyone on site.

Should I choose C13, C19 or French sockets?

It depends on your devices' power cords. Servers and network equipment mostly use C13 outlets, more powerful supplies use C19. French sockets suit devices supplied with a standard mains plug or adapter, such as a router or NAS. Bachmann's Combo outlets accept either IEC format.

Is a horizontal 1U PDU or a vertical PDU better?

A horizontal 1U strip takes one rack unit at the front or back of the cabinet and suits small network cabinets. A vertical model mounts in the rear space without using a rack unit, offers more outlets and places each one close to the device it feeds, which is why it is common in server rooms.

How do I connect a rack PDU with a C20 inlet?

A C20 inlet does not plug straight into a wall socket. It connects to a C19 outlet on a UPS or main PDU, or to a cord whose other end matches your power supply. Make sure the supplied or chosen cord is rated for the load of the connected equipment.

How is a Lindy IPower Switch controlled remotely?

IPower Switch units connect to the local network through their Ethernet port and are managed from a web interface, where each outlet is switched on or off individually. Some models add an RS-232 port for serial control. Give them a fixed address and place them on a protected management network.

What do RCM monitoring and built-in circuit breakers do on a PDU?

Residual current monitoring, marked RCM on Bachmann versions, flags leakage current before it trips the main residual current device. Built-in circuit breakers each protect a group of outlets, so an overload only switches off part of the rack rather than the whole comms room.

When is a three-phase PDU needed rather than single-phase?

A three-phase PDU, such as some APC NetShelter or Bachmann units, suits dense data centre racks that draw a lot of power and spread the load across 3 phases. It requires a matching three-phase supply in the room. For a network cabinet or a few servers, a single-phase PDU is usually enough.