1.5 m flat power cable for SmartPower RPS
Power cords
Which cord suits your sockets? Contact us for advice or a quote
Filter by
Brand
Price incl. VAT
Price incl. VAT
Cable length
Cable length
Connector 1 gender
Connector 1 gender
2 products
Sort by Available first
C13, C14 and C19 power cords for PCs, servers and racks
A power cord connects a computer, monitor, server or UPS to the mains or to a power distribution unit, and what it can do depends on the connector at each end. The range covers Schuko CEE 7/7 to C13 mains leads, C13 to C14 extension cords for racks, C19 cables for the most power-hungry equipment and dedicated leads such as the flat cable from the Ubiquiti UniFi SmartPower range. Internal PC power adapters, from SATA to PCI Express or between ATX connectors, sit alongside USB to DC plug cables for small devices.
In an office, replacing the missing lead of a tower or monitor usually calls for a CEE 7/7 to C13 cable, whose plug fits a French wall socket or a power strip. In a rack, servers and switches draw power from the C13 outlets of a PDU or UPS through short C13 to C14 cords, such as the 1 m versions designed for rack use. A UniFi network fitted with a SmartPower RPS redundant supply connects to it with the purpose-built 1.5 m flat cable.
Connector type is the first thing that separates one cord from another, followed by length, from 1 m between 2 neighbouring devices in a cabinet to 2.8 m or 4.3 m to reach a distant socket. The current rating, such as the 10 A shown on several C13 cords, must cover the device's consumption. An angled plug fits more neatly against a wall or in a shallow rack, and coloured sheathing helps identify each power circuit.
Before ordering, check the inlet on the device rather than guessing. A C13 plug fits a C14 inlet, whereas the wider C19 connector needs its own inlet and cannot be swapped for a C13. A common mistake is buying a Schuko lead for equipment that plugs into a PDU, whose outlets expect a C14 connector. Excess length also clutters the rack and obstructs airflow behind the servers.
A home user simply needs a cord that matches the socket and the device. A company fleet benefits from standardising lengths and colours in each rack, so the 2 power feeds of a redundant server can be told apart at a glance. A school or local authority equipping a computer room keeps identical spare cords on hand, which makes maintenance simpler.
Lenovo offers C13 to C14, CEE 7/7 to C13 and C19 to Schuko cords for its workstations and servers, while APC and Eaton supply cables for UPS units and PDUs, and Cisco and HPE round out cabinet equipment. Efb, Kabelmeister, S-Impuls and Bachmann cover Schuko leads and extension cords, often with angled plugs. Delock, Lindy, StarTech.com and Goobay lean towards internal adapters, USB to DC cables and mains power supplies.
Frequently asked questions
What is the difference between a C13 to C14 cord and a Schuko to C13 cable?
A Schuko CEE 7/7 to C13 cable plugs into a wall socket or power strip and powers a PC, monitor or server. A C13 to C14 cord links a device to a C13 outlet on a PDU or UPS, which is the usual format inside a rack.
What is a C19 power cord used for?
The C19 connector, wider than the C13, is fitted to servers and UPS units that draw more power. It needs a dedicated inlet on the device, so it cannot be used in place of a C13. Lenovo, for example, offers a 4.3 m C19 to Schuko CEE 7/VII cord.
How can I tell which power cord suits my device?
Look at the inlet on the back of the device and at the socket it will connect to. A C14 inlet takes a C13 plug, and a French wall socket takes a CEE 7/7 plug. Also check that the current rating on the cord, 10 A on several C13 models, covers the equipment's consumption.
What cable length should I choose for a server rack?
Inside a cabinet, a short cord such as the 1 m C13 to C14 rack cable avoids loops that clutter the back of the servers and hinder ventilation. Lengths of 2.8 m or 4.3 m are better suited to reaching a wall socket or a UPS placed further away.
Which cable works with the UniFi SmartPower redundant power supply?
The Ubiquiti UniFi range includes a 1.5 m flat cable designed for the SmartPower RPS, linking this backup supply to the network equipment. A standard mains cord cannot replace it, as the connector is specific to this system.
Are angled plugs or coloured sheathing worth having?
An angled plug frees up space behind furniture, against a wall or in a shallow rack. Coloured sheathing is mainly useful in a server room, where it distinguishes the 2 power feeds of redundant equipment and makes maintenance easier.